Annual Report on the External Quality Assessment Scheme for Routine Hematology in Korea (2017)
J Lab Med Qual Assur 2018;40:1-8
Published online March 31, 2018
© 2018 Korean Association of External Quality Assessment Service.

Young Kyung Lee1,2 and Young Min Kim2

1Department of Laboratory Medicine, Hallym University College of Medicine, Chuncheon; 2Department of Laboratory Medicine, Hallym University Sacred Heart Hospital, Anyang, Korea
Correspondence to: Young Kyung Lee
Department of Laboratory Medicine, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, 22 Gwanpyeong-ro 170beongil, Dongan-gu, Anyang 14068, Korea
Tel: +82-31-380-3930
Fax: +82-31-380-3934
E-mail: lyoungk@hallym.or.kr
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
 Abstract
Under the Routine Hematology Program of the Korean Association of External Quality Assessment Service, complete blood count (CBC) and blood cell morphology proficiency tests were performed during 2017. We conducted two trials, sent three control materials for CBC testing, and posted two cell morphology pictures on the website for each trial. Of 1,646 laboratories, the mean response rates for CBC and blood cell morphology were 96.7% and 42.0%, respectively. The distribution of equipment for CBC testing was similar to that of the previous year. The coefficient of variations for white blood cell counts, red blood cell counts, hemoglobin, hematocrit, and platelet counts were 3.7%4.7%, 2.2%2.4%, 1.5%3.0%, 5.4%6.0%, and 7.2%10.2%, respectively. More than 80% of the blood cell morphology tests were concordant among all of the trials, except for the HHI-17-03 trial. In 2017, the number of participating laboratories increased, and the performance was similar to that of the previous year.
Keywords : Laboratory proficiency testing, Blood cell count, Blood cell morphology
References
  1. Lee YK; Routine Hematology Program, Korean Association of External Quality Assessment Service. Annual report on the external quality assessment scheme for routine hematology in Korea (2016). J Lab Med Qual Assur 2017;39:53-60.
    CrossRef
  2. Klee GG, Westgard JO. Quality management. In: Burtis CA, Ashwood ER, Bruns DE, editors. Teitz textbook of clinical chemistry and molecular diagnostics. 5th ed. St. Louis (MO): Elsevier Saunders, 2012:163-203.
    CrossRef
  3. Turkey JW. Exploratory data analysis. Reading (MA):Addison-Wesley, 1977.
  4. Kwon GC, Kim J, Ra GS; Diagnostic Hematology Subcommittee;Korean Association of External Quality Assessment Service. Annual report on the external quality assessment for diagnostic hematology in Korea (2015). J Lab Med Qual Assur 2016;38:1-10.
    CrossRef