Annual Report on the External Quality Assessment Scheme for Special Protein in Korea (2017)
J Lab Med Qual Assur 2018;40:85-91
Published online June 30, 2018
© 2018 Korean Association of External Quality Assessment Service.

Hyung-Doo Park

Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
Correspondence to: Hyung-Doo Park
Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 06351, Korea
Tel: +82-2-3410-0290
Fax: +82-2-3410-2719
E-mail: nayadoo@hanmail.net
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
 Abstract
In 2017, the Korean Association of External Quality Assessment Service developed a special protein proficiency testing program that consisted of nine quantitative test items. This program was conducted twice a year using three-level control materials. Data and results of each test item were analyzed by respective institutions according to the test instruments. The report was prepared by dividing it into a common report that showed the characteristics of all the participating institutions and an organization-specific report that showed the assessment data of individual institutions. The following statistical data were presented: the number of participating institutions per group, mean, standard deviation, coefficient of variation, median, minimum value, and maximum value. The individual report was composed of a table, histogram, and Levey-Jennings chart showing the statistics for each test item. The results of the assessment of each institution and the statistical data for each classification are presented in a table, and a standard deviation index for both the company classification and classification by instruments was provided. Overall, no significant difference was observed between the number of participating institutions and the distribution of test equipment. The coefficient of variation tended to be relatively high for each test item because the concentration of quality control materials was low and the number of participating institutions was small. I believe that these statistical analysis data are useful for analyzing external quality control results of the institutions and selecting an immunoassay test instrument for special protein.
Keywords : Korean Association of External Quality Assessment Service, Laboratory proficiency testing, Special protein
References
  1. Jun SH, Song J, Song WH; Clinical Chemistry Subcommittee, Korean Association of External Quality Assessment Service. Annual report on the external quality assessment scheme for clinical chemistry in Korea (2015). J Lab Med Qual Assur 2016;38:111-9.
    CrossRef
  2. Jun SH, Song J; Clinical Chemistry Subcommittee, The Korean Association of External Quality Assessment Service. Annual report on the external quality assessment scheme for clinical chemistry in Korea (2014). J Lab Med Qual Assur 2015;37:115-23.
    CrossRef
  3. Jun SH, Song J; Clinical Chemistry Subcommittee; The Korean Association of Quality Assurance for Clinical Laboratory. Annual report on the external quality assessment scheme in clinical chemistry in Korea (2013). J Lab Med Qual Assur 2014;36:113-21.
    CrossRef
  4. Lee YW, Jeon BR, Kim JG, Jun SH, Yun YM, Chun S, et al. Annual report on the external quality assessment scheme for routine clinical chemistry in Korea (2016). J Lab Med Qual Assur 2017;39:61-75.
    CrossRef