• Sitemap
  • Contact Us

pISSN 2950-9114 eISSN 2950-9122
Article View

Report On Proficiency Testing

Lab Med Qual Assur 2020; 42(3): 112-120

Published online September 30, 2020

https://doi.org/10.15263/jlmqa.2020.42.3.112

Copyright © Korean Association of External Quality Assessment Service.

Annual Report of the Korean Association of External Quality Assessment Service on Transfusion Medicine (2019)

John Jeongseok Yang1, Jin Seok Kim1, Young Ae Lim2, Hyungsuk Kim3, and Dae-Hyun Ko1

1Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul; 2Department of Laboratory Medicine, Ajou University School of Medicine, Suwon; 3Department of Laboratory Medicine, Seoul National University Hospital, Seoul, Korea

Correspondence to:Dae-Hyun Ko
Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43- gil, Songpa-gu, Seoul 05505, Korea
Tel +82-2-3010-4504
Fax +82-2-478-0884
E-mail daehyuni1118@amc.seoul.kr
Hyungsuk Kim
Department of Laboratory Medicine, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul 03080, Korea
Tel +82-2-2072-3500
Fax +82-2-747-0359
E-mail hyungsuk.kim79@gmail.com

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

This report summarizes the 2019 survey results of the external quality assessment (EQA) scheme for the Transfusion Medicine Program (TMP) in Korea. Proficiency testing materials were prepared at the Asan Medical Center for the biannual distribution to participating laboratories. The average accuracy rates and number of participants (in parenthesis) for ten survey items were as follows: ABO typing, 99.4%–99.9% (N=875); RhD typing, 99.8%–100% (N=864); crossmatching, 90.8%–99.6% (N=760); ABO subtyping, 98.2% and 100% (N=58); Rh CcEe antigen testing, both 100% (N=55); weak D test, 97.9%–100% (N=232); antibody screening, 99.7%– 100% (N=316); direct antiglobulin test (DAT) using a polyspecific reagent, 99.6%–100% (N=273); DAT using an immunoglobulin-G monospecific reagent, both 100.0% (N=67); DAT using a C3d monospecific reagent, 95.6%–98.5% (N=67); antibody identification, 87.9%–99.2% (N=132); and ABO Ab titration, 85.7%–100% (N=134). The number of participants showed an average increase of 14% across the ten survey items, with the ABO antibody titration showing the highest increase at 83.6%. While results were generally excellent, antibody identification and ABO antibody titration results showed room for improvement. The 2019 EQA scheme for TMP has contributed to the improvement and maintenance of the participating laboratories to the program.

Keywords: Transfusion medicine, Quality improvement, Laboratory proficiency testing

Supplementary File


Share this article on :

Stats or metrics